FFU Fan Filter Unit

Key Properties

YNClean Fan Filter Units (FFU) are ceiling module diffusers consisting of a HEPA filter, fan, and control system for cleanroom, with optional pre-filter

  • Cabinet:Aluminum Galvanized steel/Stainless steel/Epoxy powder-coated steel
  • with two-piece welded plenum housing
  • Air Outlet: HEPA Filter or ULPA Filter
  • Air Inlet: Safety Net/G3/G4 pre-filter/Nylon Mesh Filter/Pleated Panel Filter/Coarse Filter
  • AC/EC FFU Group Control System
  • Optional Contro Panel with speed switch
  • Pure Copper Motor, Aluminum Turbofan

Features

Long use life, low noise, and vibration, maintenance-free, adjustable air speed, thousands of units can be easily controlled.

  • With high performance, ultra-slim design, and proven performance, the air velocity of the filter is made more even.
  • The cabinet is made of cold-rolled steel plate sprayed or made of stainless steel, compact structure and beautiful appearance;
  • Use a direct-drive high-efficiency centrifugal fan(with a noise level of 56db), with low noise, small vibration, and long life, maintenance-free.
  • Appliable optional various controllers, with pressure alarm or not (two-gear On/Off, there-gear switch, etc.)

Usual Configuration

Item Standard Model/Parameter
YN-FFU-A01 YN-FFU-A02 YN-FFU-A03 YN-FFU-A04
Cabinet(WHDmm) 575×575×230 575×1175×230 875×1175×230 1175×1175×230
Cabinet Material Aluminum Galvanized steel
Airflow Volume(m³/h) 800 1000 1500 2000
Noise 52-62dB(A)
Air Pressure(PA) 200 200 260 290
HEPA Filter Size(WHDmm) 570×570×69 570×1170×69 870×1170×69 1170×1170×69
Filter Efficiency(WHDmm) 99.995%0.3µm
Fre-Filter(Optional) Nylon Mesh Filter
Control System three-stage regulation
Supply PowerAC/EC 220V/50,60Hz, optional 110V
Total Power(W) 170W 170W 200W 240W
Weight(kg) 28kg 35kg 47kg 55kg

Available Types:

YN-FFU-A01: 2X2ft Mini BenchTop HEPA FFU Fan Filter Unit




YN-FFU-A02: 2X4ft HEPA FFU Fan Filter Unit




YN-FFU-A04: 4X4ft HEPA FFU Fan Filter Unit


Customization

YNClean is an FFU OEM manufacturer that can support customization as you request.

Custom Model: HEPA FFU Fan Filter Unit with Powder coated Steel 200mm Flange

Custom Model: Embedded Type HEPA FFU Fan Filter Unit


Custom Structural Drawing

FFU Group Control System

Quality Control

Factory Strict Test: according to international ISO14644-1 standards, with dust particle counter detection one by one to ensure quality.

Application

Widely used in semiconductors, electronics, flat panel displays, optical disk drive manufacturers, bio-industries, assembled clean rooms, and laminar flow hoods.Etc.

FAQ

What is EC fan and AC fan, and which is better?
EC (Electronically Commutated) fans and AC (Alternating Current) fans are two types of electric motors commonly used in fan applications. Each has its advantages and is suitable for specific purposes. Let’s explore the characteristics of each:

AC Fan:

  • Type of Motor: Alternating Current (AC).
  • Control: AC fans typically have basic speed control options.
  • Efficiency: AC fans are generally less energy-efficient compared to EC fans.
  • Cost: AC fans are often more affordable upfront.
  • Noise Level: AC fans may produce more noise compared to EC fans.
  • Applications: AC fans are suitable for various applications, including residential cooling, industrial ventilation, and HVAC systems.

EC Fan:

  • Type of Motor: Electronically Commutated (EC).
  • Control: EC fans offer precise speed control and can be easily integrated into control systems.
  • Efficiency: EC fans are known for their high energy efficiency, resulting in potential energy savings over time.
  • Cost: EC fans may have a higher initial cost, but the energy savings can offset this in the long run.
  • Noise Level: EC fans are often quieter compared to AC fans.
  • Applications: EC fans are commonly used in applications where energy efficiency and precise control are crucial, such as data centers, cleanrooms, and other industrial settings.

Which is Better:

The choice between EC and AC fans depends on the specific requirements of the application. If energy efficiency, precise control, and lower noise levels are critical factors, EC fans may be a better choice. However, if cost is a primary concern and the application doesn’t require advanced control features, AC fans can still be suitable.

In summary, the “better” option depends on the specific needs and priorities of the application, balancing factors such as initial cost, energy efficiency, control capabilities, and noise levels.

I have an FFU Fan Filter Unit used mainly for cleanroom manufacturing, can I use it for making my Laminar flow hood?
Absolutely! Your FFU Fan Filter Unit, primarily designed for cleanroom manufacturing, can indeed be repurposed for crafting your Laminar Flow Hood.

FFUs, known for their application in sterile isolators, seamlessly integrate into Laminar Flow (LF) hoods as well. Leveraging FFUs (Fan Filter Units) empowers you to meticulously regulate air velocity beneath each filter. Should your hood comprise multiple filters, you gain the flexibility to fine-tune velocities, ensuring uniformity across the board.

There are 3 speeds (low, medium and high). Can you ask the airflow for each of them, for the 1175x575x350 ?
TBD